With the ever-increasing use of outdoor LED or video screens, ProlyteStructures has engineered the perfect solutions for hanging screens in an efficient and safe manner. We have developed three standard screen support systems, based on the MPT, ST and CT towers. All constructions are provided with a complete set of calculations. Variations on the standard structures are available on request.

LED Screen supports require extra attention with regard to set up and structural calculations. Environmental factors, such as wind force, have to be calculated, and furthermore, the stability of both the structure and the screen needs to be ensured. All ProlyteStructures screen supports comply with the applicable regulations and standards, including wind force resistance up to wind speeds of 28 m/s.

Due to the complex interaction of forces resulting from screen surface, wind speeds, system weight and required screen height, each system is unique with respect to the calculation of the complete construction. Requirements for larger spans, higher loading or added screen height need to be calculated. ProlyteStructures’s experienced engineering department is available to assist customers with calculations and specific construction requirements.

"Due to its zero deflection, the BGR70 truss is ideal in applications with motion or LED Screens." 

LED-Screen Solutions Productsheet

Request more information

Avantages

  • LED screen supports from ProlyteStructures consist of standard products from both the tower and truss range.
  • Screen supports for a wide range of applications can be configured using your standard rental stock.

Téléchargements

Besoin d'aide?

Besoin d'aide?

Besoin de conseils sur l'un de nos produits ou services? Rendez-vous sur notre page de l'assistance, le Prolyte Campus ou
contactez-nous

Spécifications techniques

Technical specifications - Led / video screen
Allowable loading range from 500 - 5000 kg
Screen surface ranging from

6 m2 to 60 m2

 Max. Windspeed  13.8 to 28 m/s
 Design Standards  EN 13814
 

Produits pertinents

I really think truss should not be sold unless the person completes this course. There is a lot of information that is very good - people don’t always realize the complexity of trussing systems. There are many things that uniformed safety officers want, that actually at the end of the day could result in creating an issue. It’s a very good course